Tightening torque in inch pounds.
Electrical lug torque specs chart siemens.
Loose lugs create a high resistance connection to the bus bar and electrical resistance in metal causes heat.
G r d n e u t r a l e q u i p.
Siemens warrants that on the date of shipment all goods.
I have been a master electrician contractor for 42 years and have heard many times about torque values but always felt tighter was better.
A critical concept in understanding bus lug torque specifications is the fact that the pressure of the lug connection has more to do with lowering the resistance of the electrical connection than the size of the lug itself.
11 1 torque values 18 11 2 wire bending requirements 19 11 3 strap kits 17 11 4 ground fault test record external 20.
Single phase load centers siemens has a high quality and feature rich line of single phase load center products to meet applications for virtually every need.
That value goes back to that which it was tested and should guarantee that the lug cable combo will operate within the temp.
All of the major companies who manufacture electrical components have torque specifications for their equipment ask for it.
Torque wrenches and torque screwdrivers.
When a lug is torqued to that as specified by the mfg.
ł main lugs and main circuit breaker load centers have wire binding screw torque values on the wiring diagrams and circuit breaker labels neutral assemblies ł all lugs suitable for copper or aluminum wire see fimain lugs and main circuit breaker ratingsfl on page 20 ł branch neutral terminals suitable for one 14œ 4 awg copper or one.
Rise allowed as well as being able to pass a pull test.
Siemens power mod is a robust flexible and feature rich line of modular metering designed to exceed today s market demands.
Torque values go back to the point where the lug is tested with the cable for temperature rise and a pull test per ul requirements.
Internal socket size across flats inches.
Terminal wire size torque torque 35 lb in 5 lb in 35 lb in 50 lb in 20 lb in 20 lb in 20 lb in 20 lb in 25 lb in 35 lb in qp qt qpf qaf qe qnr 10 000 a n e u t r a l e q u i p.
4 6 electrical connections 8 4 7 through bus splice connections 8 9 4 8 ground bus splice connections 10.
Tightening torque in inch pounds.
Connections can create electrical noise power quality issues by vibrating and creating arc at the connection.
Tightening torque values for ilsco mechanical screw connectors.
G r d service dis co ne t n b b a r r i e r n1 1 2 41 42 siemens rainproof combination metering enclosure type 3r 2 ec 3.
How does that relate to electrical lugs.
Ensure your electricians own and know how to use a torque wrench.