Be a minimum of 36 inches wide and give access to an area that is a minimum of nine square feet with window fully open have a minimum 6 inch drop from the window sill to the ground include a ladder if the well is more than 44 inches deep.
Egress window regulations minnesota.
If the room has a door that leads directly to the exterior of the building.
Policy and purpose 16b 59 16b 75 new 326b manufactured structures.
1104 26 1 escape windows not required.
Exception thirty inches 762 mm where the aisledoes not serve more than 14 seats.
Minimum of 20 inches in clear opening width.
Measured from finish floor to clear opening.
Maximum 44 inches to window sill measured from finished floor.
Frequently used statutes minnesota building code statutes.
Dps is continuing to operate with many staff members working remotely to ensure social distancing.
Sill height not more than 44 inches above floor minimum dimensions of 36 inches.
In response to the covid 19 pandemic the minnesota department of public safety dps has adjusted or limited some services.
Thirty inches 762 mm where the aisledoes not serve more than 14 seats.
Effective dates for egress emergency escape and rescue openings.
The minimum egress window opening height is 24 high.
Thirty six inches 914 mm for level or ramped aisleshaving seating on only one side.
Emergency escape windows are allowed to be installed under decks and porches provided the location of the deck allows the emergency escape window to be fully opened and provides a path not less than 36 inches 914 mm in height to a yard or court.
The egress window must have a glass area of not less than 8 of the total floor area of room s for which it is servicing to allow the minimum amount of sufficient natural light.
Minimum 24 inches of net clear height opening.
Emergency escape windows are not required for the following conditions.
Thirty six inches 914 mm where the aisleserves less than 50 seats.
Manufactured home model rules and regulations and uniform administrative procedures of the industrialized building code commission.
Minimum 20 inches of net clear width opening.
Window wells serving an egress window shall not be less than 9 square feet in area with a horizontal length width of no less than 36 inches.
The minimum egress window opening is 20 wide.
For the latest service updates visit our dps response to covid 19 page.
The minimum opening area of the egress window is 5 7 square feet.
Openable area not less than 5 7 square feet 820 square inches.
Windows in rooms used for foster care or day care licensed or registered by the state of minnesota shall comply with the provisions of section r310 2 5 or all of the following conditions whichever is more restrictive.
R310 5 emergency escape windows under decks and porches.